A light curtain or scanner is protective only if hazardous motion stops before a person can reach it. The distance from sensing plane to hazard depends directly on stopping time. Brakes wear, loads change, control logic is modified, and valves or contactors age. A distance calculated from an old or optimistic stop time can lose its protective margin while every device still reports healthy.

Measure the complete stop

Stopping time begins when the protective device is triggered and ends when the hazardous movement reaches the defined safe state. It includes sensor response, safety logic, communication, final control elements, drive or valve response, and mechanical run-down.

SICK describes stop-time measurement as the interval from stop signal triggering to stopping of dangerous machine motion and uses the result as a basis for minimum distance. Measure at the final hazardous movement, not only at a controller bit.

Choose the applicable method

Use the standards and legal requirements for the machine and installation location. Minimum-distance equations include approach behavior, protective-device response, machine stopping time, and application-specific additions. Do not copy a formula or constant from a different market or protective arrangement.

Qualified personnel and calibrated instruments are required. SICK's guide explicitly notes that specific knowledge and equipment are needed.

Find the worst operating condition

Test maximum speed, credible load, direction, stroke position, warm and cold brakes, supply conditions, and all relevant operating modes. Gravity may make one direction worse. Regenerative drive behavior can change with DC-bus condition.

Run multiple trials. Use the worst credible result with measurement uncertainty and required margin rather than the average. Explain why the selected case bounds production.

Measure the right moving point

A press ram, blade, roll nip, robot arm, or conveyor load may not stop simultaneously with the monitored motor. Place the measurement target on the hazardous element. If several hazards exist, measure each safety function and path.

Define what counts as stopped. A small rebound, coast, or secondary gravity movement may remain hazardous after nominal velocity reaches zero.

Include protective-device response

The device and safety chain add response time. Field-set switching, cascaded devices, networked safety, muting, or multiple evaluation blocks can change it. Use the configured response, not only the catalog minimum.

Verify the active monitoring case and controller signature during the test. A measurement from a faster field or different mode is not transferable.

Recalculate and physically verify distance

Use the measured result in the applicable minimum-distance calculation. Compare the required distance with actual installation from sensing plane to hazardous point, including openings, reach-over, reach-under, and standing-behind possibilities.

If the existing distance is inadequate, move the device, reduce stop time, lower speed where controlled and validated, or redesign protection. Do not merely edit documentation.

Set a remeasurement strategy

SICK states measurement is required before initial commissioning and after significant or expected changes such as brake wear. Establish periodic testing based on machine risk, brake design, duty, environment, and trend. Remeasure after brake, clutch, drive, valve, control, safety-device, speed, load, or mechanical changes.

A maintenance replacement can improve or worsen response; only measurement confirms the new state.

Trend deterioration

Store individual stop times, not only pass or fail. Plot by date, cycle count, direction, and load. A rising trend can trigger brake service before the distance is exceeded. Investigate sudden changes in measurement setup as well as machine behavior.

Use consistent trigger and target placement so results are comparable. Maintain instrument calibration records.

Test restart prevention

The stop measurement proves run-down, but the safety function must also prevent unexpected restart while a person remains exposed. Verify reset location, presence detection, field clearing behavior, and separate start action.

For large areas, evaluate whether someone can stand behind the protective device. Distance alone does not solve that hazard.

Make evidence reviewable

Record machine identity, safety function, configuration, trigger point, hazardous element, operating conditions, loads, directions, all trials, selected worst value, uncertainty, calculation, measured physical distance, result, and next due date. Attach traces and calibrated-instrument identification.

Safety distance is a lifecycle quantity, not a one-time tape measurement. Repeated stop-time evidence shows whether wear and change are spending the margin before a person depends on it.

Define acceptance before measuring

Write the test protocol before the instrument is connected. Identify the safety input, final switching elements, hazardous motion point, velocity threshold that defines stop, number of trials, warm-up cycles, load cases, allowable variation, uncertainty treatment, and pass criterion. Specify what happens if any trial exceeds the installed-distance basis. Do not discard an outlier until its cause is understood and documented; the outlier may represent brake intermittency rather than measurement noise. Have the responsible safety engineer review both the calculation and the physical access route. This discipline prevents a convenient trace from being selected after the result is already known.

Repeatability also matters. Large scatter between trials signals a condition that a single conservative number may not explain, such as inconsistent valve release, variable drive regeneration, sticking mechanics, or an unstable trigger. Diagnose and correct the scatter before accepting the machine. Verify the stop-monitoring channel, if present, agrees with the independent instrument but do not use the same signal as both measurement and proof.

Sources checked November 4, 2026:

SICK, stop-time measurement product information:

https://cdn.sick.com/media/docs/1/11/911/Product_information_Stop_time_measurement_en_IM0077911.PDF

SICK, Guide for Safe Machinery:

https://www.sick.com/media/docs/8/78/678/Special_information_Guide_for_Safe_Machinery_en_IM0014678.PDF

SICK, V200/V300 operating instructions and minimum-distance factors:

https://www.sick.com/media/docs/3/63/763/operating_instructions_v200_work_station_extended_v300_work_station_extended_en_im0026763.pdf