Following error is the instantaneous difference between commanded and actual servo position. It grows during acceleration, load disturbance, friction, and tuning transients, then should settle as the axis reaches its target. A drive's following-error fault limit protects against a stalled, disconnected, or badly behaving axis. It does not by itself guarantee that a machined feature, robot placement, or indexing station meets its tolerance.

Name the three limits

Position-error tolerance determines when the controller declares an axis fault. Position-lock or in-position tolerance determines when the motion system considers a move complete. Process tolerance defines acceptable physical result at the tool or part. These values answer different questions and should not be copied into one another.

Rockwell Automation documents position error tolerance as a plus-or-minus fault boundary and position lock tolerance as the accepted error for end-position status. Its manual explains that tuning can establish a position-error limit from measured maximum-speed behavior.

Measure normal dynamic error

Capture command position, actual position, following error, velocity, acceleration, torque, and motion status through the production profile. Include reversal, blends, short moves, and settle. Peak error often occurs during acceleration, while process work may occur later.

Test the highest speed and acceleration, worst payload and center of gravity, hot and cold mechanics, expected lubrication state, and supply variation. A single unloaded move is not a basis for a fault limit.

Set the fault envelope with margin

The limit should exceed credible normal following error with justified margin yet remain tight enough to detect loss of control promptly. Rockwell recommends settings related to observed maximum-speed position error when changing the autotuned value. Use the exact platform guidance and units.

Do not widen the limit to suppress faults before diagnosing them. Excessive error can indicate poor tuning, motor sizing, torque saturation, binding, brake drag, encoder coupling, or command discontinuity.

Tune the loop, not the alarm

Review velocity and position loop response, inertia ratio, feedforward, filters, and mechanical resonance using the drive manufacturer's procedure. An oscillatory trace may remain inside a wide fault envelope while damaging mechanics and ruining the part.

Changing gains can affect stopping, stability, and coordinated axes. Preserve a baseline and validate the full machine after tuning. A filter that makes the trace look smooth can add phase lag and increase real error.

Define move-complete behavior

In-position status should require the error to enter a suitable window, often with a dwell or settle condition. If the PLC advances on a momentary crossing, an oscillating axis can start the next operation before it is stable.

Coordinate the window with process needs and sensor timing. A clamp, camera, or dispense step may require lower velocity or longer settle in addition to position error.

Verify mechanics independently

Encoder position may be measured at the motor while backlash, belt stretch, coupling slip, screw error, thermal growth, or structural deflection occurs downstream. Use a gauge, scale, laser, probe, or finished-part measurement at the relevant point.

A small following error proves the motor followed its command, not that the load did. Direct load feedback can improve observability but brings its own alignment and control requirements.

Test fault scenarios safely

Create approved tests for an increased load, controlled obstruction, encoder diagnostic, or reduced torque so the axis approaches the fault boundary without damaging equipment. Confirm the controller faults, removes or limits torque as designed, stops dependent motion, and reports useful evidence.

Never jam a production axis casually. Use engineering controls and the drive's test facilities where available.

Account for coordinated motion

In gantries, electronic gearing, and coordinated paths, a single-axis following error can create structural racking or path error before an individual limit trips. Monitor coordination or cross-coupled error where supported.

Set limits with the mechanical coupling and safe stop in mind. One axis stopping while another continues can be worse than the original disturbance.

Trend degradation

Store peak following error and settle time by recipe or cycle. A gradual increase can reveal lubrication loss, wear, added friction, payload drift, or brake problems. Trend alongside torque and temperature to distinguish causes.

Alarm thresholds for maintenance can be below the protective fault limit and can use persistence to avoid nuisance messages.

Document the chain of evidence

Record axis units, tuning state, motion profile, maximum observed error, selected fault margin, in-position condition, settle requirement, payload cases, independent physical measurement, and fault response. Revalidate after mechanics, motor, encoder, drive, tuning, or program changes.

Following-error protection, move completion, and process accuracy form three layers. Keeping them separate prevents a generous drive fault limit from being mistaken for precision and prevents a tight process tolerance from causing needless servo trips.

Commissioning checklist

Before release, verify encoder direction and scaling, axis units, motor and load inertia, torque limits, command filters, homing reference, software limits, following-error fault action, in-position logic, and process interlocks. Review the trace at every recipe speed and payload. Confirm an axis-disable event produces the intended mechanical state and that a vertical load remains supported. Cross-check the controller's calculated error with an independent physical observation at the load. Require a new validation record whenever a changed cam profile, gear ratio, electronic gear, or master reference can alter demanded motion. This checklist prevents a narrow tuning exercise from overlooking the machine behavior that the position limits are supposed to protect.

Sources checked November 4, 2026:

Rockwell Automation, SERCOS and Analog Motion Configuration and Startup:

https://literature.rockwellautomation.com/idc/groups/literature/documents/um/motion-um001_-en-p.pdf

Illustration note: The accompanying image is an AI-generated concept, not a drive trace, tuning report, or capability study.