Two markers can start at the same world position in an OpenUSD workcell and separate as soon as a fixture moves. A single screenshot at the home pose will miss the difference. The useful check is to sample the marker before and after moving the assembly that is supposed to carry it.

An OpenUSD prim normally inherits transforms from its ancestors. A transformable prim can also reset its transform stack, which makes its authored transform independent of that ancestor chain. The prim stays in the same place in the scene hierarchy. Looking only at its path, or at the values of its local translate operation, will therefore miss the effect of a reset.

Test a moving slide with two markers

The fixture below gives both markers a local X offset of 2 stage units. It authors a parent translation of 0 at time code 0 and 12 at time code 1. Both markers sit under the same slide in the scene hierarchy, but only the Reference marker resets its stack.

from pxr import Gf, Usd, UsdGeom

stage = Usd.Stage.CreateInMemory()

carrier = UsdGeom.Xform.Define(stage, "/Slide")

motion = carrier.AddTranslateOp()

motion.Set(Gf.Vec3d(0, 0, 0), 0)

motion.Set(Gf.Vec3d(12, 0, 0), 1)

mounted = UsdGeom.Xform.Define(stage, "/Slide/Mounted")

reference = UsdGeom.Xform.Define(stage, "/Slide/Reference")

for marker in (mounted, reference):

marker.AddTranslateOp().Set(Gf.Vec3d(2, 0, 0))

reference.SetResetXformStack(True)

def positions(frame):

cache = UsdGeom.XformCache(Usd.TimeCode(frame))

return tuple(

cache.GetLocalToWorldTransform(marker.GetPrim())

.ExtractTranslation()[0]

for marker in (mounted, reference)

)

assert positions(0) == (2.0, 2.0)

assert positions(1) == (14.0, 2.0)

assert not mounted.GetResetXformStack()

assert reference.GetResetXformStack()

print(positions(0), positions(1))

With OpenUSD 0.26.11, the output is (2.0, 2.0) at time code 0 and (14.0, 2.0) at time code 1. The first world position includes the parent slide translation at each sample. The second stays at X=2 because the reset discards the parent transform. Here both stage samples are explicitly authored, and no physics engine, controller, meter conversion, or time-to-seconds conversion is involved.

Run the check on the composed workcell

Pick one component that should ride on the assembly and a fixed datum you can measure alongside it. Open the complete stage used by the downstream application, with the intended layers and variants active. Sample a pose where the carrier has moved far enough to distinguish the expected outcomes. For a pure translation like the test above, compare the displacement of the carrier with the displacement of the attached marker. When the carrier also rotates, compare the full world-space transforms or transform a known point. World position alone can miss a rotation about the marker origin.

If the marker does not move as expected, check the reset flag on the marker and on the prims between it and the carrier. An intermediate reset can cut off inheritance even when the marker itself has no reset. Also verify that the composed slide transform actually changes at the sampled time codes. Create a fresh transform cache after editing the stage so the measurement reflects the edit.

Keep the prim path, the stage variant, both time codes, the expected relationship and the measured transforms with the review. That record lets another reviewer repeat the check after a new asset export without relying on how the home pose looks.

Sources

OpenUSD UsdGeomXformable API reference for transform operation order and reset behavior

https://openusd.org/release/api/class_usd_geom_xformable.html

OpenUSD UsdGeomXformCache API reference for composed transform queries and cache behavior

https://openusd.org/release/api/class_usd_geom_xform_cache.html