A vacuum generator that reaches a high final vacuum on sealed metal may perform poorly on cardboard, foam, textiles, wood, or rough castings. Porous and leaky parts admit air continuously. The generator must remove that inflow while maintaining enough pressure difference for the load.
Maximum vacuum describes a low-leakage limit
Catalog maximum vacuum is typically measured under defined conditions with little or no leakage. It shows the attainable pressure state, not how much incoming air the device can overcome on a porous part.
Suction flow describes how rapidly the generator removes air. For a leaking workpiece, the operating point occurs where generator capacity and leakage balance. If leakage exceeds capacity at the required pressure, vacuum plateaus below the pickup threshold.
Leakage belongs to the part family
Cardboard porosity varies with grade, coating, moisture, recycled content, printing, creases, and damage. Castings vary with texture and parting lines. Bags and textiles change as they deform.
Test a representative worst-case set, not one golden sample. Define the acceptable material envelope with purchasing and process teams so a supplier change does not silently invalidate the gripper.
Seal leakage and through-part leakage are different
Air can pass under the cup lip because of roughness, grooves, curvature, dust, or wrinkles. It can also pass through the bulk material. A larger or softer cup may improve edge sealing but cannot stop flow through porous material.
Use cup material and geometry supported for the surface. Excessive softness can collapse, reduce effective area, or increase wear. A foam sealing element can conform to rough surfaces but has its own leakage and service-life behavior.
Flow paths add pressure loss
Long hoses, small fittings, manifolds, filters, and valves restrict suction flow. Generator capacity at its port is not the same as flow available at a remote cup.
Place the generator and valves appropriately, size lines from manufacturer data, and measure vacuum near the gripper. A central gauge can hide pressure drop and local leakage.
Multiple cups share limited capacity
One missed cup can become a large open leak that collapses vacuum for every cup on a common manifold. Use check valves, flow restrictors, sectional circuits, or independent generators when the process requires fault isolation.
Verify behavior with one cup uncovered and with the smallest part that does not seal every zone. The desired response may be inhibited pickup, continued holding by other zones, or a controlled stop; define it before commissioning.
Thresholds need dynamic evidence
Set the pickup threshold from required holding margin, cup area, orientation, acceleration, and uncertainty. A low threshold chosen only to avoid timeouts can permit motion with inadequate force.
Record vacuum versus time. A porous part can cross the threshold briefly and then fall as it flexes or another valve opens. Require stable qualification and monitor the minimum pressure through the real robot path.
Air-saving modes may cycle frequently
Some systems turn the generator off after reaching a threshold and restart when vacuum falls. On a porous part, continuous leakage can cause rapid cycling or make shutoff unsuitable.
Review hysteresis, restart frequency, valve duty, and pressure ripple. Energy-saving logic must not allow holding pressure to cross the dynamic requirement between cycles.
Mechanical support can reduce dependence on vacuum
Stops, forks, nests, clamps, or edge guides can carry shear and support a part during pressure variation. They are especially useful for flexible sheets and bags that change shape.
Mechanical features must engage across tolerances and must not prevent the seal. Credit them only when their load path is documented and tested.
Maintenance is part of capacity
Filters, silencers, porous foam, cup lips, and generators degrade. Trend evacuation time, steady vacuum, air consumption, and restart rate. A slow increase in continuous flow can reveal wear or contamination.
Define service criteria rather than waiting for failed pickups. After replacing a cup or generator, repeat the worst-leakage test with the approved settings.
Acceptance test
Use minimum supply pressure, longest permitted hose, maximum simultaneous demand, worst part porosity, worn-but-serviceable seals, maximum payload, and highest required acceleration. Measure pickup time, steady vacuum, minimum dynamic vacuum, leakage response, and release.
Also test an open cup, partial seal, double pick, and deformed part. Confirm that diagnostics identify a failed pickup without creating unsafe or damaging motion.
Engineering rule
For porous workpieces, select the generator from suction-flow curves at the required vacuum and validate the assembled flow path. Maximum vacuum alone is not a capacity rating for leakage.
The gripper succeeds when available suction flow exceeds worst permitted leakage with enough pressure margin throughout the robot cycle.
Model leakage as a distribution
Measure steady airflow or pressure decay across enough parts to capture material variation, then select a percentile and margin consistent with the process risk. One worst-looking sample may not represent humid stock, edge damage, or a supplier change. Store the material lot with test data.
Separate initial evacuation from continuous holding. Large internal volume dominates the first interval, while porosity dominates steady consumption. Generator selection and cycle timing must satisfy both. A reservoir can mask short demand but cannot compensate indefinitely for leakage beyond supply capacity.
Track compressed-air use as well as vacuum. Oversizing flow can rescue unreliable parts at high energy cost and noise. Mechanical sealing improvements, zoning, or a different gripping principle may be more robust than continuously increasing air consumption.
Sources checked November 4, 2026:
Schmalz, vacuum generators and suction-flow fundamentals:
https://www.schmalz.com/en/support/know-how/vacuum-knowledge/the-vacuum-system-and-its-components/vacuum-generators
Schmalz, vacuum suction cups and holding-force fundamentals:
https://www.schmalz.com/en/support/know-how/vacuum-knowledge/the-vacuum-system-and-its-components/vacuum-suction-cups
Illustration note: The accompanying image is an AI-generated concept. It is not a leakage test, product curve, material specification, or deployment record.